Horizontal High Pressure High Speed Cylindrical Sterilizer (HHPA1)

Specifications:-

  • As per IS Mark 3829 Part II. (Size:-400mm X 1100mm)
  • End ring hydraulically formed without joint to sustain required pressure. All other jointly Argon Arc welded.
  • Chamber & Jacket made from ASI 316L material.
  • Resin bond fibre glass wool insulation with SS 316L steel cover.
  • Door made from ASI 316L material.
  • Heat resistance high density silicon door gasket
  • Boiler made from ASI 316L material.
  • Unique Multi port valve Located at Top Controls all operation Manually, control for the entire cycle of the operation.
  • Two Safety valves for chamber & jacket
  • Pressure switches economies power consumption & accident.
  • Work on 134 degree C temperature & 32 PSI (2.1 Kg cm²)
  • Hydraulic Tested pressure 2 time of working pressure
  • Lo water cut off device for heater protection.
  • Pressure lock device for Door.
  • Power supply 18kw 440V 3 Phase
  • First cycle time 35 min.
  • Subsequent 9 min.
  • Easy to read compound gauge for the chamber and pressure gauge for the jacket.
  • Gauge glass tube with automatic closing safety valve
  • Powerful ejector for drying.
  • sterilizer Mounted on Heavy duty powder coated stand with floor levelling.
  • Best Suited for rapid sterilizations of instruments for Cardiac, Ortho, Neuro & Urology.
  • Heaters 6 KW 3 Nos, high quality Emerson heater.

Optional:-

  • Watering Vacuum pump.
  • Fully automatic microprocessor base.
  • Loading Carriages & Trolley.
  • Temperature recorder.

Detail Specification:-

  • Automatic Microprocessor Controlled Machine.
  • Fully Programmable with microprocessor-based technology.
  • Control and monitor a variety of sterilizing cycles, depending as per load
  • alarm system for cycle failure or any interruption.
  • Document printing, chart recorder and alpha numeric recorder for monitoring operational history.
  • Control panel have document of all cycle information including key transition points in the cycle & alarms the sterilization process.
  • A standby manual operation facility to be incorporated in case of automatic failure.
  • The Sterilizer mounted on a strong sturdy stainless steel stand.
  • Temperature adjustable from 121° to 134° C.
  • Working pressure 15 psi to 31 psi.
  • Automatic Digital Minute Timer.
  • The panel have integral alarms that ring, flash, or otherwise display information when temperature set or fall below.
  • Automatic signals at both ends of the autoclave indicating doors locked when both
  • doors are locked and secure.
  • Loading carriage & transfer trolley of SS with lock wheel.